Festo CTEU-PB Electronics Description page 44

Universal bus node, fieldbus protocol profibus-dp
Table of Contents

Advertisement

2. Commissioning
Electric modules
Designation
Bus node CTEU for
PROFIBUS-DP
Valve terminal
CPV10-GE-PT-8 16
valves with I-Port con-
nection
Valve terminal
CPV14-GE-PT-8 16
valves with I-Port con-
nection
Input module CTSL M12
Input module CTSL M8
Valve terminal
VTUG-1-16 valves with
I-Port connection
Valve terminal
VTUG-17-32 valves
with I-Port connection
Valve terminal
VTUG-33-48 valves
with I-Port connection
Valve terminal
VTOC-Interlock /
VTUG-Interlock 1-16
valves with I-Port con-
nection
Valve terminal
VTOC-Interlock /
VTUG-Interlock 17-32
valves with I-Port con-
nection
2-8
Module
Identifier
1)
indicator
EN50170
CTEU-PB
0x00
CPV10-8
0x21
CPV14-8
0x21
CTSL M12
0x11
CTSL M8
0x11
VAEM-L1-S-
0x21
8-PT
VAEM-L1-S-
0x23
16-PT
VAEM-L1-S-
0x25
24-PT
VAEM-L2-S_
0x13, 0x21
PTL-16
VAEM-L2-S_
0x33
PTL-32
Allocated address
space
Siemens
Inputs
0
16DO
0
16DO
0
16DI
2 bytes / 16 I
16DI
2 bytes / 16 I
16DO
0
32DO
0
37
0
32DI 16DO
4 bytes /
(18 used I)
32DX
4 bytes /
(18 used I)
Festo P.BE-CTEU-PB-OP+MAINT-EN en 1208NH English
Outputs
2 bytes / 16 O
2 bytes / 16 O
0
0
2 bytes / 16 O
4 bytes / 32 O
6 bytes / 48 O
2 bytes/16 O
4 bytes/32 O

Hide quick links:

Advertisement

Table of Contents
loading