2. Commissioning
2.2
Preparing the bus node for configuration
2.2.1 Addressing the bus node

2.2.2 Modules/devices at I-Port connection 1 and 2

Festo P.BE-CTEU-PB-OP+MAINT-EN en 1208NH English
A maximum of three modules can be configured: the bus
node itself as well as up to two connected I-Port devices
(e.g. valve terminals).
The bus node has an address space of up to 16 bytes inputs
and 16 bytes outputs:
Max_Data_Len = 32 (20
The counting mode is module-oriented for inputs and out-
puts, starting with the device at I-Port connection 1, followed
by the device at I-Port connection 2
Enter the identifiers corresponding to the physical sequence
of the modules in your configuration program, starting with
the device at I-Port connection 1, followed by the device at
I-Port connection 2.
)
h
2-7