A. Technical appendix
A.1

Technical data

General
Temperature range
– Operation
– Storage/transport
Relative air humidity in accordance with
IEC 60770
Protection class in accordance with EN 60529,
bus node mounted completely, plug connector
inserted or provided with protective cap
Protection against electric shock
(protection against direct and indirect contact in
accordance with IEC/DIN 60204-1)
Electromagnetic compatibility (EMC)
– Emitted interference
– Resistance to interference
3)
Vibration and shock
Tested in accordance with DIN/IEC 68 / EN 60068
– Vibration (part 2 - 6)
– Shock (part 2 - 27)
– Continuous shock (part 2 - 29)
Dimensions
– Width
– Length
– Height
Weight (bus node without cable and without
CAPC-... or I-Port device)
1) Observe that connected devices may only satisfy a lower protection class, a smaller temperature
range, etc.
2) The bus node is intended for use in an industrial environment. Measures for interference suppres-
sion may need to be implemented in residential areas.
3) Explanation of the severity level
level"
Festo P.BE-CTEU-PB-OP+MAINT-EN en 1208NH English
-5 ... +50 °C
-20 ...+70 °C
93 % at 40 °C
IP65/67
with corresponding cable from Festo accessories
by means of PELV circuit
(Protected Extra Low Voltage)
2)
See declaration of conformity
www.festo.com
Severity level (SL) for assembly on ...
Wall: SL 2, H-rail: SL 1
Wall: SL 2, H-rail: SL 1
Wall and H-rail: SL 1
40 mm
91 mm
50 mm
90 g
following table "Explanation on vibration and shock – severity
1)
A-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents