A. Technical appendix
General
Materials
– Housing
– Fibre-optic cable, DIL switch cover
– Threaded sleeve M12
– Threaded bush M3
– Seals
– Screws
Corrosion protection
Explanation on vibration and shock – severity level
Severity level 1
(SL 1, in accordance with EN 60068, part 2 – 29)
Severity level 2
(SL 2, in accordance with EN 60068, part 2 – 27)
A-4
RoHS-compliant
PA, reinforced
PC
Brass, galvanically nickel-plated
Brass
Nitrile rubber
Galvanised steel
CRC 2
Medium protection against moderate corrosion
through contact with typical industrial atmo-
sphere (e.g. water vapour condensation, coolant
and lubricants).
Vibration:
0.15 mm path at 10 ... 58 Hz;
2 g acceleration at 58 ... 150 Hz
Shock:
±15 g at 11 ms duration;
5 shocks per direction
Continuous shock:
± 15 g at 6 ms duration;
1000 shocks per direction
Vibration:
0.35 mm path at 10 ... 60 Hz;
5 g acceleration at 60 ... 150 Hz
Shock:
±30 g at 11 ms duration;
5 shocks per direction
Continuous shock:
n. a.