Connection Technology For Fieldbus Interface - Festo CTEU-PB Electronics Description

Universal bus node, fieldbus protocol profibus-dp
Table of Contents

Advertisement

1. Installation
D-sub
Pin
socket
1
2
3
4
5
6
7
8
9
Housing
1)
Type FBS-SUB-9-GS-DP-B, part no. 532216, IP65
2)
The repeater control signal CNTR-P is a TTL signal.
Tab. 1/3:
Pin allocation of the fieldbus interface of the bus node

1.5.5 Connection technology for fieldbus interface

T-TAP function
1-16
Fieldbus plug
Signal
1)
from Festo
connection
-
Screening
-
n.c.
B
RxD/TxD-P
-
CNTR-P
-
DGND
-
VP
-
n.c.
A
RxD/TxD-N
-
n.c.
Clamp strap
Screening
Note
Use protective caps or blanking plugs to seal unused con-
nections. You will then achieve protection class IP65.
Connection with fieldbus plugs from Festo
With a fieldbus plug, you connect the bus node conveniently
to the fieldbus without the use of pre-made cable.
Use the fieldbus plug, type FBS-SUB-9-GS-DP-B from the Festo
accessories (
Accessories
You can disconnect this fieldbus plug from the bus node
without interrupting the fieldbus cable (T-TAP function).
Designation
Connection to functional earth
not connected
Reception/transmitted data P
2)
Repeater control signal
Data reference potential (M5V)
Supply voltage plus (P5V)
not connected
Reception/transmitted data N
not connected
Connection to functional earth