The 0-10 V analog inputs have an input impedance of about 35 kΩ.
l
The 0-30 V analog inputs have an input impedance of about 110 kΩ.
l
The analog outputs have an output impedance of about 200 Ω.
l
The maximum output current of each analog output is 10 mA. Exceeding the maximum
output current will result in damage to the analog output module.
Aux Sensors
Connector type
HDB15M
Use
Low Front Laser, optional Side Lasers
Pin No.
Hardware
1
RS232_VERT1_TXD
2
RS232_VERT2_TXD
3
RS232_FOOT_TXD
4
5V_SW1
5, 10
SW_20V_VERT
6, 7, 8
GND
9
5V_SW2
11
RS232_VERT1_RXD
12
RS232_VERT2_RXD
13
RS232_FOOT_RXD
14
5V_SW3
15
SW_20V_FOOT
Chapter 6: Connectivity
Pin No.
Designation
8
ANALOG_IN8
9
ANALOG_OUT1 0 – 20 V Range
10
ANALOG_OUT2 0 – 20 V Range
11
ANALOG_OUT3 0 – 20 V Range
12
ANALOG_OUT4 0 – 20 V Range
13, 14, 15 GND
Designation
Software
USB_1_and_2_Power 5 V @ 1 A (shared with USB port 1)
Vertical_Laser_Power
USB_1_and_2_Power 5 V @ 1 A (shared with USB port 2)
USB_3_Power
Foot_Laser_Power
LD Platform User's Guide, 11970-000 Rev E
Page 65 of 142
Notes
0 – 30 V Range
Notes
/dev/ttyUSB5 (side lasers)
/dev/ttyUSB6 (side lasers)
/dev/ttyUSB7 (low front laser)
20 V @ 300 mA (side lasers)
/dev/ttyUSB5 (side lasers)
/dev/ttyUSB6 (side lasers)
/dev/ttyUSB7 (low front laser)
5 V @ 1 A (shared with USB port 3)
20 V @ 150 mA (low front laser)