2.5.4 PL 6xxx PLC input/output systems with HSCI interface

System PL

PL 62xx
System PL, consisting of PLB 620x basic
module and I/O modules.
One module must be in the HSCI
system if no UEC 11x is used
Available with 4, 6 or 8 slots
HSCI interface
Connections for TS and TT touch probes
Safety-relevant PLC inputs/outputs
For an overview of the available I/O
modules, see "I/O modules" on page 91.
Mounted on standard NS 35 rails
(DIN 46 227 or EN 50 022)
PLB 6204
ID 591832-xx
PLB 6206
ID 630054-xx
PLB 6208
ID 630055-xx
PLB 6204 FS ID 586789-xx
PLB 6206 FS ID 622721-xx
PLB 6208 FS ID 620927-xx
July 2013
The PLC inputs and outputs of the iTNC 530 HSCI are available via the external
modular PL 6xxx PLC input/output systems.
The PL 6xxx consists of the PLB 6xxx basic module and one or more I/O
modules. The basic modules are connected to the MC main computer via the
HSCI interface.
Note
The MC xxxx main computer of the iTNC 530 HSCI does not have an
integrated PLC, and has no connections for TS or TT touch probes. In order
to operate the control, at least the PL 62xx system PL (when using a
CC 6106) or the UEC 11x controller unit with integrated inverter and PLC is
necessary (the system PL is integrated in the UEC).
The PLC inputs/outputs are configured with the PC software IOconfig.