Module 9287 General status requests regarding VNC clients

PLC Module 9287 is used to program the following status requests regarding
control and assignment of multiple operator terminals (IPC, ThinClient):
Number of VNC clients
Status of focus assignment
Name of the active VNC client (master)
List of VNC clients
Individual name of a VNC client from the client list
Constraints:
Call only from a submit/spawn job
If no name is configured for a client, its MAC address is returned in the PLC
strings.
Mode 3/4: The sequence and numbering of the client list can vary from one
boot instance to the next, since this information depends on the point in
time at which the clients register themselves in the system.
Call:
PS
B/W/D/K <Mode>
0: Number of active clients suitable for focus assignment
1. Status of focus assignment
2: Name of the active VNC client
3: List of all clients
4: Name of client n from the client list
PS
B/W/D/K <Timeout [ms]>
Module rounds up to the next 100 ms limit
0: Default timeout 3000 ms
PS
B/W/D/K <Additional parameter 1>
Mode 0: - - -
Mode 1: - - -
Mode 2: Address of PLC string
Mode 3: Address of PLC string
Mode 4: Address of PLC string
PS
B/W/D/K <Additional parameter 2>
Mode 0: - - -
Mode 1: - - -
Mode 2: - - -
Mode 3: - - -
Mode 4: Number of clients n
CM
9287
PL
B/W/D
<Error code>
0: No error
1: PLC error, error code in PLC error word (see below)
>= 100: Operating-system error
PL
B/W/D
<Status>
Mode 0: Number of clients
Mode 1: Focus assignment 0/1: Enabled/disabled
Mode 2: - - -
Mode 3: - - -
Mode 4: - - -
HEIDENHAIN Technical Manual iTNC 530 HSCI