Log Function - HEIDENHAIN iTNC 530 HSCI Technical Manual

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

Log function

752
The Cycles 451 and 452 save log files in the PLC:\ directory, from which you
can see the results of the individual measuring points. TNCscope can be used
for a graphic evaluation (import the table). On the Extras -> Info tab, you can
display additional information about the measurement and a short legend of
the individual measured data.
The files are saved under PLC: as TCHPR45x_<axis name>.A. The columns
created may vary depending on the conditions for measurement.
Data with the designation REF are to be understood with respect to the
machine coordinate system. Data with the designation ERROR are measured
errors in the coordinate system of the rotary axes. Data with the designation
OPT are the errors to be expected in the coordinate system of the rotary axes
after an optimization.
The data can be imported for evaluation (e.g. in TNCscope, Excel).
TNCscope: Open the file in TNCscope by selecting:
File – Import Table. Then select the file to be opened.
The Import Table dialog box opens.
Select Fixed sampling interval and enter the value 1 ms in the Time unit
field.
Select "/" as the column separator and confirm your entry with OK.
HEIDENHAIN Technical Manual iTNC 530 HSCI