Status Of Options That Have Been Set - HEIDENHAIN iTNC 530 HSCI Technical Manual

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

Status of options
that have been set
146
Module 9067 Status of software settings
PLC Module 9067 enables you to request status information about software
settings. Module 9067 can currently be used to interrogate the software
options set in the SIK.
Call:
PS
B/W/D/K <Mode>
0: Interrogate whether SW option is set in the SIK
PS
B/W/D/K <Number>
If mode is 0: Number of SIK option
CM
9067
PL
B/W/D
<Status>
Status of SIK option (if mode is 0):
0: Not set
1: Set
Error code:
Marker
Value
Meaning
M4203
0
Function was performed correctly
1
Error code in W1022
W1022
1
Invalid value for number
2
Invalid value for mode
HEIDENHAIN Technical Manual iTNC 530 HSCI