3.25 Analog nominal value output

308
In the HSCI system, analog nominal-value outputs are available via the
CMA-H 04-04-00, e.g. for controlling spindles and auxiliary axes.
The CMA-H 04-04-00 is an optional SPI expansion module (ID 688721-xx). It
adds four analog nominal-value outputs to the CC 61xx controller unit or the
UEC 1xx.
Controller unit
Number of CMA-H 04-
04-00 modules per unit
CC 61xx
2
UEC 11x
1
The CMA-H 04-04-00 is supported by the following CC 61xx and UEC 11x:
CC 6106 as of ID 662636-01 (as of index A, 29.06.2010)
CC 6108 as of ID 662637-01 (as of Index A, 29.06.2010)
CC 6110 as of ID 662638-01 (as of Index A, 29.06.2010)
UEC 111 as of ID 625777-02 (as of Index A, 03.02.2010)
UEC 112 as of ID 625779-02 (as of Index A, 03.02.2010)
Note
The analog nominal value outputs can only be accessed via the NC, and
not via the PLC. The PL 6xxx provides PLC analog outputs, see "Analog
PLC inputs/outputs" on page 285.
With software version 60642x-02 and higher, the CMA-H can generally
also be used to control axes that are interpolated together with other
digital axes. However, please discuss such applications with your contact
person at HEIDENHAIN beforehand.
Max. number of nominal-
value outputs
8
4