Consideration of I0 when using synchronous motors:

If I0 differs too much from Irated, then the utilization display can be adapted
via MP2312.x. In this case you must set MP2312.x = I
Example for the behavior of I0 and Irated with an OSY155F-EcoDyn motor:
12
10
8
6
4
2
0
0
500
In the diagram you can see that:
I0 = 12.8 A, Irated = 9.8 A, nRated = 3000 rpm
For the synchronous motor:
Mactl = kT · Iactl
Mrated = kT · Irated
Mrated = f(n)

Module 9166 Momentary utilization of the drive motor

The evaluation through MP2312.x is already calculated in the utilization of the
drive motor.
Call:
PS
B/W/D/K <Axis>
Axis-specific: Dependence on MP4020 bit 14
CM
9166
PL
B/W/D
<Utilization of the drive in %>
Error code:
Marker
Value
Meaning
M4203
0
No error
1
Control has no current controller
MP2312.x
Factor for utilization of motors
Input:
0 to 1 000.000
0: Factor = 1