X104—Safety:
Dual-channel PLC
inputs (on the front)
July 2013
Connections on the front of the UxC 11x FS:
8 dual-channel PLC inputs:
I0.A to I7.A
I0.B to I7.B
Terminal
Signal designation Assignm. / Function
1a
+24 V.A
2a
+24 V.B
3a
+24 V.C
4a
Do not assign
5a
I4.B
6a
I5.B
7a
I6.B
8a
I7.B
9a
I4.A
10a
I5.A
11a
I6.A
12a
I7.A
1b
Do not assign
2b
Do not assign
3b
Do not assign
4b
Do not assign
5b
I0.B
6b
I1.B
7b
I2.B
8b
I3.B
9b
I0.A
10b
I1.A
11b
I2.A
12b
I3.A
Note
If the integrated PLC inputs do not suffice for your application, you can
connect up to 7 additional external PL 61xx expansion PLs to the
UxC 111FS via the HSCI interface.
3.16 Digital PLC inputs/outputs
24 V supply of the outputs O0.A to O7.A
24 V supply of the outputs O0.B to O7.B
24 V supply of the outputs O8.A to O15.A
24 V inputs
24 V inputs