SIK Options:

All available software options and their corresponding numbers are listed in a
table. The check marks in the first column indicate which software options
have been enabled on your control.
To enable additional software options, proceed as follows:
Press the MOD key and enter the code number SIK to display the input
mask for SIK functions.
In the table on the right side of the screen, use the arrow keys or the mouse
to select the software option you want to enable.
Pressing the Set Option button or the SET OPTION soft key opens a window
in which you can enter the code number for the desired software option
under Enter Key Code. HEIDENHAIN can give you the code number after
you state your SIK number.
Enter the code number and confirm the entry by pressing the Apply button
or the SET OPTION soft key.
If this is done successfully, the message Option <number> has been set
appears, and the option is checked in the table.
When you leave this table of SIK functions by pressing the END soft key or the
END key, you are requested to reboot the control if you have made any
changes. Press the emergency stop button and press the Reboot Now! button
or the REBOOT NOW soft key to reboot the control and activate the changes.

To display the corresponding number of machine-parameter indexes:

In OEM.SYS, enter the code word PWMPARAMETER = followed by the required
number of machine-parameter indexes MP2xxx.y for the current and speed
controller.
In OEM.SYS, enter the code word AXISNUMBER = followed by the required
number of remaining machine-parameter indexes.