I/O Modules Pld-H And Pla-H - HEIDENHAIN iTNC 530 HSCI Technical Manual

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

3.7.16 I/O modules PLD-H and PLA-H

PLD-H 16-08-00
Pin layout
PLD-H 08-16-00
Pin layout
July 2013
Connector
Function
X11
PLC inputs, channel A
X12
PLC inputs, channel A
X21
PLC outputs, channel A
Diagnosis (meanings of the LEDs):
Red (X11/pin 1) status LED
• Flashes: status of I/O module OK
• Continuously on or off: error on I/O module
Yellow (per output): Status of the output
Error recognition:
Short circuit: A short circuit is reported when a current >= 20 A flows
for approximately 3 ms. Both the output-specific message and the group
message are modal.
After the short circuit has been removed, the PLC must reset the output
before it can be activated again.
Connector
Function
X11
PLC inputs, channel A
X21
PLC outputs, channel A
X22
PLC outputs, channel A
Diagnosis (meanings of the LEDs):
Red (X11/pin 1) status LED
• Flashes: status of I/O module OK
• Continuously on or off: error on I/O module
Yellow (per output): Status of the output
Error recognition:
Short circuit: A short circuit is reported when a current >= 20 A flows
for approximately 3 ms. Both the output-specific message and the group
message are modal.
After the short circuit has been removed, the PLC must reset the output
before it can be activated again.