KNX
Planning and Application
4.9

Sequence

The DGN/S 1.16.1 features a function Sequence. A sequence is a string of up to a maximum of 10 scenes.
They are recalled successively with their parameterized brightness transitions. The function Sequence is
controlled or stopped via the group switch telegrams. The set function Sequence can be repeated up to
255 times. If required, it is also possible to program continuous repetition. In this way, it is possible to pro-
gram running lights or lighting effects without additional logic or timer modules with the DGN/S.
The different brightness values of the sequence are set in the scenes which are used. The setting of the
scene is undertaken in the
Enable function Scene in the parameter window
quently enabled in
The timing of the function Sequence is defined in
in which the scenes are recalled after one another, is also determined there. In sequence operation a sce-
ne can be used several times. The
dow
General, page 27, the parameter Enable sequence time curve (one curve per gateway) is set. Only
one time dependent sequence can be set for each DGN/S. Using the switch communication objects of the
lighting group, the course of the sequence can be used for every lighting group as often as required.
In the following, a coloured running light is used to describe, for example, how to parameterize the function
Sequence for a facade or for the lighting in a showroom window.
Task:
First of all the three primary colours red, green and blue run consecutively before the mixed colours
blue/red (magenta) and red/green (yellow) are set.
Brightness
100 %
0 %
Step:
The colour sequences should run in the following order:
The coloured lamps are divided into 3 lighting groups
Lighting group 5: red
Lighting group 6: green
Lighting group 7: blue
First of all, the timing arrangement, the sequence steps with transition time and run time are set in the
Parameter window
Step
Scene No.
Transition time
Runtime
142 2CDC 507 114 D0201 | DGN/S 1.16.1
Parameter window Scene x
Parameter window Scenes
Parameter window
Scene 2
OFF
Scene 1
Scene 3
Red
Green
1
2
3
Sequence, page 87:
1
2
1 red
2 OFF
45 s
1 s
1 min
1 s
on page 85, which is enabled via the parameter
Parameter window
General, page 27, and then is subse-
on page 84.
Parameter window
Sequence, page 87. The sequence,
Sequence, page 87, is enabled if in
Scene 4
Green OFF
Scene 6
Scene 5
Magenta
Blue
4
5
3
4
5
6
2 green
5 + red =
3 green
4 blue
OFF
Magenta
45 s
1 s
45 s
32 s
1 min
1 s
1 min
30 s
Parameter win-
Scene 7
Scene 2
Blue OFF
OFF
Scene 8
Yellow
6
7
8
9
7
8
9
7 + green
6 blue
2 OFF
OFF
= yellow
1 s
32 s
5.5 s
1 s
30 s
5 s
Time