2.9.3 Welding Condition Adjustment Display

2
Basic Operations
2.9
Overriding Welding Condition Function
5. Press [CANCEL]
– The job content display appears.
• Only the welding condition data that have been set are
displayed.
For example, when the weaving operation is not set, "***"
is displayed for "WEAV AMPLITUDE."
NOTE
And, when COMARC function is not used, "U/D
CONDITION" and "L/R CONDITION" are not displayed.
• When the instruction such as ARCOF are executed, the
adjustment is disabled and "***" is displayed for each
welding condition.
1
2
3
4
5
6
7
CURRENT
Move the cursor to the data and press the TUNING key to adjust the
welding current value.
The welding current is specified by the following instructions:
• The instruction item (AC=) to ARCON instruction
• The current value set in the welding start condition file (ASF# (*)
specified by ARCON instruction
(When an enhanced type file is used, the data will not be
overwritten.)
• The instruction item (AC=) to ARCSET instruction
• The instruction item (AC=) to ARCCUR instruction
• The set value by AWELD instruction
When ARCOF instruction is executed, the welding current adjustment is
disabled.
When COMARC function is used,  "U/D CONDITION" will be changed
in proportion to the welding current adjustment.
On the contrary, adjusting U/D CONDITION will not change the welding
current value.