Parameters For The Units To Adjust Conditions - YASKAWA DX100 Instructions Manual

Options, for multi-layer welding function
Hide thumbs Also See for DX100:
Table of Contents

Advertisement

156446-1CD
DX100

2.9.4 Parameters for the Units to Adjust Conditions

Parameter
Meanings
S3C1200
The units for adjusting the welding current value (When the specific key is
pressed once)
Min. units for the current value: 1 A, Min. units for the command value: 0.01
V
S3C1201
The units for adjusting the welding current value (When the specific key is
pressed consecutively)
Min. units for the current value: 1 A, Min. units for the command value: 0.01
V
S3C1202
The units for adjusting the welding voltage value (When the specific key is
pressed once)
Min. units for the voltage value: 0.1 V or 1 %, Min. units for command value:
0.01 V
S3C1203
The units for adjusting the welding voltage value (When the specific key is
pressed consecutively)
Min. units for the voltage value: 0.1 V or 1 %, Min. units for the command
value: 0.01 V
S3C1204
The units for adjusting the speed (When the specific key is pressed once)
Min. units: 1 cm/min
S3C1205
The units for adjusting the speed (When the specific key is pressed
consecutively)
Min. units: 1 cm/min
S3C1206
The units for adjusting the weaving single amplitude (When the specific key
is pressed once)
Min. units: 0.1 mm
S3C1207
The units for adjusting the weaving single amplitude (When the specific key
is pressed consecutively)
Min. units: 0.1 mm
S1E51
The units for adjusting the sensing U/D condition (When the specific key is
pressed once)
Min. units: 1 A
S1E52
The units for adjusting the sensing U/D condition (When the specific key is
pressed consecutively)
Min. units: 1A
S1E53
The units for adjusting the sensing L/R condition (When the specific key is
pressed once)
Min. units: 0.1 A
S1E54
The units for adjusting the sensing L/R condition (When the specific key is
pressed consecutively)
Min. units: 0.1 A
2
Basic Operations
2.9
Overriding Welding Condition Function
When using the specific keys to adjust a condition, the units for each
condition can be set by the following parameters.
Set the multiplication of the minimum unit of each condition.
2-38
Initial
Value
1
1
1
1
1
1
1
1
1
1
1
1
HW0485806

Advertisement

Table of Contents
loading

Table of Contents