7.2 Connecting The PCX-RIX8+ (Remote Input Expander with 4 PGMs)
PCX-RIX8+
The PCX-RIX8+ is an input expander that
supports 8 inputs (not inertia).
It also supports normally closed (double pole),
DEOL and SEOL input wiring.
There are 4 programmable PGMs.
The PCX 46 will support up to 4 x Remote
Input Expanders.
7.2.1 PCX-RIX8+ Technical Specification
PCX-RIX8+ (Input Expander)
Input Voltage
Current Consumption
Inputs
Input EOL Resistor
Values
Normal
Burglary Alarm
Fault
Masking (6k8)
PGM1 - PGM4
PGM1 - PGM4
PGM1 - PGM4
Dimensions (plastic
box)
Dimensions (PCB)
Colour and Casing
Indication
Temperature
Front and rear tamper protected
PCX 46 App Installation Reference
9-15V
30mA
Programmable
DEOL, NC, 3 Resistor (Grade 3)
1k / 1k DEOL Range
0k5 to 1k4
1k5 to 5k9
6k to 8k1
8k2 to 17k
100mA each
Normal state: 12V
Active state: 0V
173 x 125 x 32mm
128 x 87 x 16mm
White 3mm ABS with clear polycarbonate window
LEDs (Power, OK and Fault)
Storage: -20°C to +60°C
Certified: -10°C to +40°C
Nominal: -10°C to +50°C
Page: 31
4k7 / 2k2 DEOL Range
1k4 to 2k9
4k2 to 7k8
8k to 11k3
11k6 to 22k
4k7 / 4k7 DEOL Range
3k7 to 8k3
8k4 to 10k2
10k3 to 14k9
15k to 22k