    3.2 Important Installation Notes ....................10 3.3 Communication Loom ......................11 3.4 Power and Battery Connections for the PCX 46 APP L ..............12 3.5 Power and Battery Connections for the PCX 46 APP S ..............13 4. Input Connections ........................14 4.1 Normally Closed Input Wiring ....................
  • Page 3: System Overview

    PCX 46 App Installation Reference 1. System Overview is wired control panel that can have a maximum of 46 inputs. There are two versions PCX 46 App available: S = Small box (Security Grade 2), L = Large box (Security Grade 3).
  • Page 4: The Devices

    PCX 46 App Installation Reference 1.1 The Devices All PCX peripherals; LCD keypads, readers, expanders etc. are connected via the D1-, D2+, D3 and D4 terminals. This is an example of what a typical PCX bus may look like. General Principles:...
  • Page 5 PCX 46 App Installation Reference 1.1.1 RS-485 Wiring Wiring Format Bus range Cable type Screened Cable Daisy Chain Range Star Range 4 core alarm cable 300m Use when bus located near 6 core alarm cable No limit. 230VAC mains doubling D1 (0v)
  • Page 6: Pcx 46 App Input Mapping Overview

    PCX 46 App Installation Reference Input Mapping Overview: PCX 46 App Input Numbers DEVICES Address PCX 46 App PCX-RIX8 / PCX-RIX8+/ PCX-RIX8+PSU /PCX-RIX32-WE 9-16 PCX-RIX8 / PCX-RIX8+/ PCX-RIX8+PSU /PCX-RIX32-WE 17-24 PCX-RIX8 / PCX-RIX8+/ PCX-RIX8+PSU /PCX-RIX32-WE 25-32 PCX-RIX8 / PCX-RIX8+/ PCX-RIX8+PSU /PCX-RIX32-WE...
  • Page 7: Out Of The Box

    PCX 46 App Installation Reference 2. Out of the box 1. Unscrew and remove the cover of the (Figure 1). The Printed circuit PCX 46 App PCX 46 App board is located to the top right hand side. (Figure 2) 2.
  • Page 8: The Printed Circuit Board

    PCX 46 App Installation Reference 3. The Printed Circuit Board 12: Earth connection 1: Case Tamper Hold-Off Jumper Connects the earth 2: PGM 1 (Relay output. See page: 16) 13: 17V connection 3: Speaker connection Connects the AC transformer 17V supply Connects a 16ohm speaker.
  • Page 9: Technical Specification

    PCX 46 App Installation Reference 3.1 Technical Specification Programmable Outputs Power Rating Normal State Active State PGM 1 Relay, 3A, max 30V Changeover NC & NO Changeover NC & NO Speaker 16 ohms No tones Repeat RKP tones & internal sounder...
  • Page 10: Important Installation Notes

    PCX 46 App Installation Reference EN50131-6:2008 Rated Output In accordance with EN50131-6:2008, the standby times and effective output currents depend on the PCX 46 APP Security Grade of the system and how 230V mains missing fault is signalled to the Alarm Receiving Centre.
  • Page 11: Communication Loom

    PCX 46 App Installation Reference 3.3 Communication Loom The ATE low power outputs are programmed in the engineer function: ‘Program Outputs->Endstation PGMs”. Purple (ATE Output 8: Mains Fail (0052)) Light Grey (ATE Output 10: Unused 0000)) White (ATE Output 9: Battery Fault (0053))
  • Page 12: Power And Battery Connections For The Pcx 46 App L

    PCX 46 App Installation Reference 3.4 Power and Battery Connections for the PCX 46 APP L Panel Power Supply Input Nominal Range Mains Supply Voltage AC 230V AC at 50Hz -15% +10% Transformer Rating 45VA 18.5V at 2.5A PCX 46 APP...
  • Page 13: Power And Battery Connections For The Pcx 46 App S

    PCX 46 App Installation Reference 3.5 Power and Battery Connections for the PCX 46 APP S Panel Power Supply Input Nominal Range Mains Supply Voltage AC 230V AC at 50Hz -15% +10% Transformer Rating 18VA 18V at 1.0A PCX 46 APP...
  • Page 14: Input Connections

    PCX 46 App Installation Reference 4. Input Connections NOTE: If ‘Normally Closed’ (double pole) wiring is selected, the Diagnostics on the keypad will show "4K Alarm and 2K2 Tamper". Input Resistance 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range...
  • Page 15: Grade 2 Deol (Double End Of Line) Input Wiring

    PCX 46 App Installation Reference 4.2 Grade 2 DEOL (Double End of Line) Input Wiring Input Resistance 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range 4k7 / 4k7 DEOL Range Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3...
  • Page 16: Output (Pgm) Connections

    PCX 46 App Installation Reference 5. Output (PGM) Connections Normal State: 12V Active State: 0V Current: 100mA 5.1 XPGM Connections If Inputs 7 and 8 are programmed as ‘unused’, these inputs can be used as 2 further outputs (known as XPGM1 and XPGM2 which can be programmed in ‘PROGRAM OUTPUTS’).
  • Page 17: External Sounder Connections

    PCX 46 App Installation Reference 6. External Sounder Connections 6.1 Grade 3 External Sounder Wiring Pyronix Grade 3 External Sounders: Deltabell Plus, Deltabell X, Invincibell Plus, Invincibell X 6.2 Grade 2 External Sounder Wiring with a Grade 3 Bell Pyronix Grade 3 External Sounders:...
  • Page 18: Grade 2 External Sounder Wiring

    PCX 46 App Installation Reference 6.3 Grade 2 External Sounder Wiring Pyronix Grade 2 External Sounders: Deltabell E, Invincibell E Page: 18...
  • Page 19: Connecting The Pcx Peripherals

    PCX 46 App Installation Reference 7. Connecting the PCX Peripherals 7.1 Connecting The PCX-LCD Keypad (PCX-LCD/EX) The PCX LCD keypad is used for programming and user operation. can have up to 6 x PCX-LCD/EX PCX 46 APP keypads installed. NOTE: See the keypad installation manual for the LED and button explanations.
  • Page 20 PCX 46 App Installation Reference Enter the required Address [0-6] and press t Press a to exit. You must now address is from the menu "INSTALL KEYPADS/READERS". 7.1.3 Adding The PCX LCD Keypad (From the Engineer Menu) Enter the engineers menu and scroll to 'INSTALL KEYPADS/READERS' and press t. Please see the Programming Manual for more information.
  • Page 21 PCX 46 App Installation Reference 7.1.5 Connecting The PCX LCD Keypad Inputs (Grade 2) Input Resistance 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range 4k7 / 4k7 DEOL Range Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3...
  • Page 22: Connecting The Internal Tag Reader (Pcx-Prox/Int)

    PCX 46 App Installation Reference 7.2 Connecting The Internal Tag Reader (PCX-PROX/INT) The Internal Tag Reader can have 2 inputs connected. It can be used as an arm, disarm, entry control or an access control device. NOTE: See the reader installation manual for the LED and button explanations.
  • Page 23 PCX 46 App Installation Reference 7.2.3 Adding The Internal Tag Reader (From the Engineer Menu) Enter the engineers menu and scroll to 'INSTALL KEYPADS/READERS' and press t. Please see the Programming Manual for more information. 7.2.4 Connecting The Internal Tag Reader Inputs...
  • Page 24: Connecting The External Proximity Reader (Pcx-Ext-Bk)

    PCX 46 App Installation Reference 7.3 Connecting The External Proximity Reader (PCX-EXT-BK) The External Proximity Reader can be used as either an arm, disarm, entry control or an access control device. NOTE: See the reader installation manual for the LED and button explanations.
  • Page 25 PCX 46 App Installation Reference 7.3.3 Adding the External Tag Reader (From the Engineer Menu) Enter the engineers menu and scroll to 'INSTALL KEYPADS/READERS' and press t. Please see the Programming Manual for more information. 7.3.4 Connecting a Mag Lock and a Request to Exit Button to the External Tag Reader The diagram show the relay mag lock control switching positive and shows a normally open request to exit button, and takes “0V”...
  • Page 26 PCX 46 App Installation Reference 7.3.6 Using the External Tag Reader for Arming and Entry Control 7.3.7 Using the Request to Exit button 7.3.8 Using the External Tag Reader Disarming Page: 26...
  • Page 27: Connecting The Pcx-Rix8I (Remote Input Expander With Inertia)

    PCX 46 App Installation Reference 7.1 Connecting The PCX-RIX8i (Remote Input Expander with Inertia) 7.1.1 The PCX-RIX8i Expander PCX-RIX8i The PCX-RIX8i is an input expander that supports 8 normal or inertia inputs (also known as fast inputs). It also supports NC (normally closed), DEOL and SEOL input wiring.
  • Page 28 PCX 46 App Installation Reference 7.1.4 Addressing the PCX-RIX8i (From The Expander) 7.1.5 Adding the PCX-RIX8i (From the Engineer Menu) Enter the Engineers menu and scroll to 'INSTALL RIX' and press t. Please see the Programming Manual for more information.
  • Page 29 PCX 46 App Installation Reference 7.1.7 Wiring Inputs on the PCX-RIX8i (DEOL: Grade 2) Input Resistance: 1k / 1k DEOL Range NOTE: The resistance values are fixed to 1K Alarm and 1K Tamper Normal: 0k5 to 1k4 on the PCX-RIX8i expander.
  • Page 30 PCX 46 App Installation Reference 7.1.9 Wiring Fast Inputs on the PCX-RIX8i (DEOL: Grade 2) Connecting a Roller Shutter Connecting a Shock Sensor NOTE: These resistances are fixed to 1K Alarm and 1K Tamper and Input Resistance: cannot change. 1k / 1k DEOL Range NOTE: The programming menu "PROGRAM INPUTS"...
  • Page 31: Connecting The Pcx-Rix8+ (Remote Input Expander With

    PCX 46 App Installation Reference 7.2 Connecting The PCX-RIX8+ (Remote Input Expander with 4 PGMs) PCX-RIX8+ The PCX-RIX8+ is an input expander that supports 8 inputs (not inertia). It also supports normally closed (double pole), DEOL and SEOL input wiring.
  • Page 32 PCX 46 App Installation Reference 7.2.2 PCX-RIX8+ Input Configuration Input 1k / 1k DEOL 4k7 / 2k2 DEOL 4k7 / 4k7 DEOL Resistance Range Range Range Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3 Burglary Alarm 1k5 to 5k9...
  • Page 33 PCX 46 App Installation Reference 7.2.5 Wiring Inputs on the PCX-RIX8+ (Normally Closed) Input Resistance 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range 4k7 / 4k7 DEOL Range Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3...
  • Page 34 PCX 46 App Installation Reference 7.2.7 Wiring Inputs on the PCX-RIX8+ (DEOL - Grade 3) Input Resistance 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range 4k7 / 4k7 DEOL Range Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3...
  • Page 35: Connecting The Pcx-Rix8+Psu (Remote Input Expander With Psu)

    PCX 46 App Installation Reference 7.3 Connecting The PCX-RIX8+PSU (Remote Input Expander with PSU) PCX-RIX8+PSU The PCX-RIX8+ is an input expander that supports 8 inputs (not inertia) and has a 2.5A power supply. It supports normally closed (N/C), DEOL and 3EOL input wiring.
  • Page 36 PCX 46 App Installation Reference 7.3.2 PCX-RIX8+PSU Input Configuration Input Resistance 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range 4k7 / 4k7 DEOL Range Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3 Burglary Alarm 1k5 to 5k9...
  • Page 37 PCX 46 App Installation Reference 7.3.5 Wiring Inputs on the PCX-RIX8+PSU (Normally Closed) Input Resistance 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range 4k7 / 4k7 DEOL Range Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3...
  • Page 38 PCX 46 App Installation Reference 7.3.7 Wiring Inputs on the PCX-RIX8+PSU (DEOL: Grade 3) Input Resistance 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range 4k7 / 4k7 DEOL Range Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3...
  • Page 39: Connecting The Pcx-Rix32-We (Remote Wireless Expander)

    PCX 46 App Installation Reference 7.4 Connecting The PCX-RIX32-WE (Remote Wireless Expander) PCX-RIX32-WE The PCX-RIX32-WE is a input expander that supports Two Way wireless Enforcer technology. It will allow 32 wireless inputs, 32 wireless keyfobs and 2 wireless bells to be...
  • Page 40 PCX 46 App Installation Reference Addressing Example: Having 32 wireless inputs on the PCX 46 APP PCX-RIX32-WE: DEVICE A This expander will learn all 32 wireless keyfobs and 2 wireless bells.  Address 0 = 8 wireless inputs (Inputs 9-16) ...
  • Page 41: Connecting The Pcx-Rox8R8T (Remote Output Expander)

    PCX 46 App Installation Reference 7.5 Connecting The PCX-ROX8R8T (Remote Output Expander) PCX-ROX8R8T The PCX-ROX8R8T is an output expander that supports 8 way relays and 8 transistor outputs. will support up to 2 x Remote PCX 46 APP Output Expanders.
  • Page 42 PCX 46 App Installation Reference 7.5.4 PCX-ROX8R8T Output Connections Page: 42...
  • Page 43: Connecting The Pcx-Rox16R+Psu Expander (Remote Output Expander With Psu)

    PCX 46 App Installation Reference 7.6 Connecting The PCX-ROX16R+PSU Expander (Remote Output Expander with PSU) PCX-ROX16R+PSU The PCX-ROX16R+PSU is an output expander that supports 16 way relays and has a 2.5A power supply. will support up to PCX 46 APP x Remote Output Expanders.
  • Page 44 PCX 46 App Installation Reference 7.6.3 Adding The PCX-ROX16R+PSU (From the Engineer Menu) Enter the engineers menu and scroll to 'PROGRAM OUTPUTS' and then 'O/P Module O/Ps?' and press t. Please see the Programming Manuals for more information. 7.6.4 PCX-ROX16R+PSU Connections...
  • Page 45: The Gprs, Lan And Pstn Modems

    PCX 46 App Installation Reference 8. The GPRS, LAN and PSTN Modems Connecting the modems in the large box Connecting the modems in the small box GPRS or LAN Modem GPRS or LAN Modem PSTN Modem PSTN Modem The PSTN modem should be located at the...
  • Page 46: The Pstn Modem (Digi-1200)

    PCX 46 App Installation Reference Connecting the modems to the control panel 8.1 The PSTN Modem (Digi-1200) The PSTN DIGI-1200 card is a fast modem and enables communication via PSTN line using Contact ID and SIA Level 1/ Level 3 as well as remote uploading/ downloading.
  • Page 47: The Gprs Modem (Digi-Gprs)

    PCX 46 App Installation Reference 8.2 The GPRS Modem (DIGI-GPRS) The GPRS modem card (DIGI-GPRS) fits inside the Besides PCX 46 APP. communications with the PyronixCloud and App, it has the HomeControl+ following operations: Send Alarms to the ARC: With the DIGI-GPRS it is possible to send alarm events the monitoring station via Contact ID IP an SIA IP protocols.
  • Page 48: Connecting To The Upload/Download Software

    LCD menu or the UDL InSite Software provided PCX 46 APP free of charge. It can be downloaded from http://www.pyronix.com/pyronix-downloads.php. The connection between control panel and UDL software can be done in the following ways: 8.4.1 Serial Connection (RS232)
  • Page 49 PCX 46 App Installation Reference 8.4.3 Modem Connection DIGI-1200 (PSTN) On the Panel: (Ensure that the panel and remote PC are connected to a suitable PSTN line). 1. Enter the Engineer Menu (code 9999) 2. Scroll the menu (x button) until the “Options Up/Downloading”...
  • Page 50: En 50131 Terminology

    PCX 46 App Installation Reference 9. EN 50131 Terminology EN50131 Language Language PCX 46 APP Disarm Unset Day or Disarmed Mode Unset State (may be relevant to a specific partition) Personal Attack (PA) Hold Up (HU) Bypass Inhibit Unused Isolated...
  • Page 51: Notes

    PCX 46 App Installation Reference NOTES Page: 51...