Connecting The Pcx Peripherals; Connecting The Pcx-Lcd Keypad (Pcx-Lcd/Ex) - Pyronix PCX 46 APP Installation & Reference Manual

Hide thumbs Also See for PCX 46 APP:
Table of Contents

Advertisement

7. Connecting the PCX Peripherals

7.1 Connecting The PCX-LCD Keypad (PCX-LCD/EX)

The PCX LCD keypad is used for programming
and user operation.
The
can have up to 6 x PCX-LCD/EX
PCX 46 APP
keypads installed.
NOTE: See the keypad installation manual for
the LED and button explanations.
NOTE: The total number of keypads and readers
that can be installed on the
7.1.1 Technical Specification
PCX-LCD/EX (LCD Keypad)
Supply Voltage:
Current Consumption:
Inputs 1 & 2
Input EOL Resistor Values
Normal
Burglary Alarm
Fault
Masking (6k8)
PGM:
PGM Normal State:
PGM Active State:
Dimensions:
EN50131 Certified:
Colour and Casing:
Indication:
NOTE:
Temperature
Front and rear tamper protected
7.1.2 Addressing The PCX LCD Keypad (From the Keypad)
Addressing
Hold the d key for more than 5 seconds.
'SECURITY CODE' will be displayed. Enter '2000'
The default address given is '00'.
PCX 46 App Installation Reference
is 6.
PCX 46 APP
9-15V DC
<50mA
Programmable, DEOL, SEOL, 3 Resistor
1k / 1k DEOL Range
0k5 to 1k4
1k5 to 5k9
6k to 8k1
8k2 to 17k
100mA
Floating
0V
144 x 99 x 34mm
Grade 3
White 3mm ABS
LEDs (OK, Fault, Alarm, Disarmed, Tamper)
The LCD display may not function correctly at temperatures
below +2ºC but this will not affect the system operation.
Storage: -10°C to +40°C
Certified: -10°C to +40°C
Nominal: -10°C to +40°C
Page: 19
4k7 / 2k2 DEOL Range
1k4 to 2k9
4k2 to 7k8
8k to 11k3
11k6 to 22k
4k7 / 4k7 DEOL Range
3k7 to 8k3
8k4 to 10k2
10k3 to 14k9
15k to 22k

Advertisement

Table of Contents
loading

Table of Contents