9. EN 50131 Terminology

Language
PCX 46 APP
ARM
Disarm
Day or Disarmed Mode
Personal Attack (PA)
Bypass
Unused
Bell / External Sounder / SAB
Main Sounder / Speaker
Prox card, Tag, or wireless keyfob

10. Access Levels

Level 1: Access by any person; for example the general public.
Level 2: User access by an operator; for example customers (systems users).
Level 3: User access by an engineer; for example an alarm company professional.
Level 4: User access by the manufacturer of the equipment.
Note: Alarm, tamper and fault indications will automatically be cleared within 3 minutes. If a user has
finished viewing the information they can terminate the display instantly by pressing the t key.

11. Compliance

As per EN 50131-1 the
In Grades 1 & 2 I&HAS when an I&HAS or part thereof is in a set state:
a) access to the supervised premises or part thereof, via an entry/exit route, shall be prevented, or
b) opening the door to the entry/exit route shall initiate an entry procedure, or
c) indication of the set/unset status shall be provided.
In Grades 3 & 4 I&HAS when an I&HAS or part thereof is in a set state:
a) access to the supervised premises or part thereof, via an entry/exit route, shall be prevented, or
b) opening the door to the entry/exit route shall initiate an entry procedure.
App HomeContol+ not certified IMQ-Security Systems.
PCX 46 App Installation Reference
EN50131 Language
Set
Unset
Unset State (may be relevant to a specific partition)
Hold Up (HU)
Inhibit
Isolated
External Warning Device (self-powered is assumed)
Device combining internal warning device with audible indicator
(using different tones and volumes)
Digital Key
is capable of supporting all conditions A,B and C: -