EN50131-6:2008
Rated Output
In accordance with EN50131-6:2008, the
Security Grade of the system and how 230V mains missing fault is signalled to the Alarm Receiving Centre.
Power supplies are rated in accordance with the requirements of EN50131-6, which are related to the maximum
battery size that can be accommodated in the housing and vary according to the grade of the system in which
they are installed, as per the following table:
Electrical Capability
Example Battery Model
Yuasa NP7-12
Yuasa NP17-12
PCB Current Consumption
PCX 46 APP
Quiescent
User Code and Tag Guessing
4-digit codes
6-digit codes
Disallowed codes
All codes
According to EN50131-3:2009 Annex B
According to spec of manufacturer of RFID
components used
The below table specifies ATS (Alarm Transmission System) performance criteria in
accordance with the requirements of EN50136-1:2012 and EN50136-2.
Notification Equipment
Remotely powered external sounder
Self-powered external sounder
Main Communication Path (ATS)
Second Communication Path (ATS)
GRADE 2 option A, B, C and D with DIGI-LAN (SP5) or DIGI-GSM (SP2) and DP1 (DIGI-LAN or DIGI-GSM
with DIGI-1200)
The use of the DIGI-GPRS (SP5) or DIGI-LAN (SP5) Option "Grade 3 Option A, B and D are supported."

3.2 Important Installation Notes

Ensure wiring is done to the national wiring regulations in the country where the installation is
taking place. In the UK, this is BS 7671 Requirements for electrical installations; IET Wiring
Regulations (17th edition). If in doubt, consult a local qualified electrician.
Ensure that a readily accessible disconnect device incorporated in the premises installation wiring
shall be provided external to the equipment with a contact separation of at least 3,0mm and
connected as closely as possible to the supply. Example: Fused Spur Unit
When fixing external wires, ensure that means are provided in the installation to prevent the SELV
(Safety Electrical Low Voltage) or signal circuits from coming into contact with live parts of the
power supply circuit. Wires shall be fixed near their terminal blocks.
The end of stranded conductor shall not be consolidated by soft soldering at places where the
conductor is subjected to contact pressure. Example: Must not solder ends of wires which are to be
secured in detector and control panel terminal connectors.
On completion of wiring use tie-wraps to prevent any loose wires causing a safety hazard (material
of cables tie shall be rated at least HB or better).
Cables ties and hoses shall be separate for power supply cable and SELV (Safety Electrical Low
Voltage) wirings.
Size of protective bonding conductors: minimum section 1.5mm². Example: Electrical Earth wire
connections.
PCX 46 App Installation Reference
PCX 46 APP
EN50131-6 Rating. Maximum Load
80mA
10,000
100,000
None
16
12
Option A
Optional
ATS 2
Optional
standby times and effective output currents depend on the
Grade 2
Environmental
Operational
Storage
Humidity
Dimensions
PCX 46 APP
L
PCX 46 APP
S
Printed Circuit Board
PCX 46 APP
EN50131 Grading
= Grade 2.
PCX 46 APP
S
Grade 2 Criteria
Option B
2
Optional
1
ATS 2
Optional
Page: 10
0.5A
1.2A
-10°C to +40°C, Certified
-20°C to +60°C
75%
390 x 305 x 100mm
Weight: 11.5kg inc
battery
250 x 297 x 82mm
Weight: 4.8kg inc battery
170 x 90 x 30mm
= Grade 3
PCX 46 APP
L
Option C
Optional
Optional
ATS 2
ATS 1
Option D
Optional
Optional
ATS 3
Optional