3.4 Power and Battery Connections for the PCX 46 APP L
Panel Power Supply Input
Mains Supply Voltage AC
Transformer Rating
PCX 46 APP
Panel Power Supply Output
Output Voltage
Output Current
PCX 46 APP
Power Supply Type A.
Battery Charging Specification
Float Voltage
Battery low voltage cut off
Recharge time
Fuses
230V Mains Fuse for mains terminals
NOTE: The battery connect 'kickstart' button (see Item 9, page 8) is used to power-up the control panel
when there is no mains supply present. For example: if you wish to program a panel that is being fitted
in a new-build premises before the mains supply has been fully installed. To use it – Hold for 5 seconds
and then release.
IMPORTANT: Ensure that the battery Jumper is in the correct position for the capacity of battery that
you have connected – otherwise the panel may under-charge a large battery or over-charge and damage
a smaller battery.
PCX 46 App Installation Reference
Nominal
230V AC at 50Hz
45VA
L
Nominal
13.7V DC
1.5A Continuous
L
13.8v DC
10.5v
<24 Hours
Value
T500mA H anti-surge slow blow 250V
Control Panel Type
Standby battery capacity current
Standby battery capacity current
Page: 12
Range
-15% +10%
18.5V at 2.5A
Range
10-15V DC
2.0A peak, during battery charging
300mA (3Ah to 6Ah)
700mA (7Ah to 17Ah)
Type
Ceramic
Need help?
Do you have a question about the PCX 46 APP and is the answer not in the manual?
Questions and answers