Grade 2 Deol (Double End Of Line) Input Wiring; Grade 3 Mask/Fault Input Wiring - Pyronix PCX 46 APP Installation & Reference Manual

Hide thumbs Also See for PCX 46 APP:
Table of Contents

Advertisement

4.2 Grade 2 DEOL (Double End of Line) Input Wiring

Input Resistance
Normal
Burglary Alarm
Tamper

4.3 Grade 3 Mask/Fault Input Wiring

Input Resistance
Normal
Burglary Alarm
Fault
Masking (6k8)
Tamper
All inputs are programmed in "PROGRAM INPUTS" in the Engineer menu.
PCX 46 App Installation Reference
1k / 1k DEOL Range
0k5 to 1k4
1k5 to 5k9
<0k5 or <17k
1k / 1k DEOL Range
0k5 to 1k4
1k5 to 5k9
6k to 8k1
8k2 to 17k
<0k5 or <17k
4k7 / 2k2 DEOL Range
1k4 to 2k9
4k2 to 7k8
<1k4 or >22k
4k7 / 2k2 DEOL Range
1k4 to 2k9
4k2 to 7k8
8k to 11k3
11k6 to 22k
<1k4 or >22k
Page: 15
4k7 / 4k7 DEOL Range
3k7 to 8k3
8k4 to 10k2
<3k7 or >23k
4k7 / 4k7 DEOL Range
3k7 to 8k3
8k4 to 10k2
10k3 to 14k9
15k to 22k
<3k7 or >23k