4. Input Connections

NOTE: If 'Normally Closed' (double pole) wiring is selected, the Diagnostics on the keypad will show "4K
Alarm and 2K2 Tamper".
Input Resistance
Normal
Burglary Alarm
Fault
Masking (6k8)
Tamper
All inputs are programmed in "PROGRAM INPUTS" in the Engineer menu.

4.1 Normally Closed Input Wiring

PCX 46 App Installation Reference
1k / 1k DEOL Range
0k5 to 1k4
1k5 to 5k9
6k to 8k1
8k2 to 17k
<0k5 or <17k
4k7 / 2k2 DEOL Range
1k4 to 2k9
4k2 to 7k8
8k to 11k3
11k6 to 22k
<1k4 or >22k
Page: 14
4k7 / 4k7 DEOL Range
3k7 to 8k3
8k4 to 10k2
10k3 to 14k9
15k to 22k
<3k7 or >23k