7.2 Connecting The Internal Tag Reader (PCX-PROX/INT)

The Internal Tag Reader can have 2 inputs connected. It can
be used as an arm, disarm, entry control or an access
control device.
NOTE: See the reader installation manual for the LED and
button explanations.
NOTE: The total number of readers that can be installed on
the
is 5. The readers are installed on the same
PCX 46 APP
bus as the keypads.
7.2.1 Technical Specification
PCX-PROX/INT (Internal Tag Reader)
Input Voltage:
Supply Current:
Inputs:
Input EOL Fixed Resistor
Values:
Shared Outputs:
Colour and Casing:
Indication:
Temperature:
Dimensions (H x W x D):
Front and rear tamper protected
NOTE: If the PCX-PROX/INT (Internal Tag Reader) is programmed as an 'Arm/Disarm' device, 2 inputs
are enabled. If the PCX-PROX/INT is programmed as 'Entry Control' or 'Access Control' only 1 input is
enabled.
7.2.2 Addressing The Internal Tag Reader (From the Reader)
PCX 46 App Installation Reference
12VDC (9-15V DC range)
<30mA Quiescent. <90mA Maximum
Programmable. 2 inputs; DEOL
Alarm=4K7 / Tamper=2K2
Normal: 1k4 to 2k9
Burglary Alarm:4k2 to 7k8
Tamper: <1k4 or >22k
Switched negative 150mA (Max)
White 3mm ABS
LEDs (Alert, Alarm, Fault, Tamper, Disarmed)
Storage:-20°C to 60°C
Certified: -10°C to 40°C
Nominal: -20°C to 60°C
97 x 40 x 23mm
Page: 22