1.2
Input Mapping Overview:
PCX 46 App
DEVICES
PCB
PCX 46 App
PCX-RIX8 / PCX-RIX8+/ PCX-RIX8+PSU /PCX-RIX32-WE
PCX-RIX8 / PCX-RIX8+/ PCX-RIX8+PSU /PCX-RIX32-WE
PCX-RIX8 / PCX-RIX8+/ PCX-RIX8+PSU /PCX-RIX32-WE
PCX-RIX8 / PCX-RIX8+/ PCX-RIX8+PSU /PCX-RIX32-WE
PCX-LCD/EX
PCX-LCD/EX / PCX-PROX/INT*
PCX-LCD/EX / PCX-PROX/INT*
Total
NOTE 1: 1 x PCX-RIX32-WE can be connected to the
are separated into 4 addresses (each address enables 8 wireless inputs). It is possible to mix the wired
and wireless remote expanders. For more information please see page: 39.
*NOTE 2: If the PCX-PROX/INT (Internal Tag Reader) is programmed as an 'Arm/Disarm' device, 2
inputs are enabled. If the PCX-PROX/INT is programmed as 'Entry Control' or 'Access Control' only 1
input is enabled.
1.3
Output Mapping
PCX 46 App
DEVICES
PCB
PCX 46 App
Digi/ATE Outputs (using communication loom)
PCX-ROX8R8T / PCX-ROX16R+PSU
PCX-ROX8R8T / PCX-ROX16R+PSU
PCX-RIX8+/ PCX-RIX8+PSU
PCX-RIX8+/ PCX-RIX8+PSU
PCX-RIX8+/ PCX-RIX8+PSU
PCX-RIX8+/ PCX-RIX8+PSU
PCX-LCD/EX
PCX-LCD/EX / PCX-PROX/INT / PCX-EXT-BK/W
PCX-LCD/EX / PCX-PROX/INT / PCX-EXT-BK/W
PCX-LCD/EX / PCX-PROX/INT / PCX-EXT-BK/W
PCX-LCD/EX / PCX-PROX/INT / PCX-EXT-BK/W
PCX-LCD/EX / PCX-PROX/INT / PCX-EXT-BK/W
Total
PCX 46 App Installation Reference
PCX 46
Page: 6
Input Numbers
Address
PCB
1-8
0
9-16
1
17-24
2
25-32
3
33-40
0
41-42
1
43-44
2
45-46
46
App. This expander allows 32 inputs which
Address
PCB
Loom
0
1
0
1
2
3
0
1
2
3
4
5
Output Numbers
5 (2 shared)
10
1-16
17-32
1-4
1-4
1-4
1-4
1
1
1
1
1
1
69