Standards Relevant To The Emc Directive - Mitsubishi Electric Q170MSCPU User Manual

Melsec q series, motion controller
Table of Contents

Advertisement

7 EMC DIRECTIVES

7.1.1 Standards relevant to the EMC Directive

Certification
EN55011:2007/A2:2007
Radiated emission
EN61000-6-4:2007
EN55011:2007/A2:2007
EN61131-2:2007
(Power line)
EN55022:2006/A1:2007
(Electrical communication port)
Conducted emission
EN61000-4-2:1995
+A1:1998+A2:2001
Electrostatic discharge
immunity
EN61000-4-3:2006
Radiated immunity
EN61000-4-4:2004
Electrical fast transient/
burst (EFT/B) immunity
EN61000-6-2:2005
EN61131-2:2007
EN61000-4-5:2006
Surge immunity
EN61000-4-6:2007
+A:2001
Conducted immunity
EN61000-4-11:2004
Short interruptions immunity
EN61000-4-11:2004
Voltage dip
EN61131-2:2007
EN61131-2:2007
Voltage dip immunity
(Note-1): This product is an open type device (a device designed to be housed inside other equipment) and must be installed inside a
conductive control panel.
The corresponding test has been done with the programmable controller installed inside a control panel.
(Note-2): QP : Quasi-peak value
(Note-3): For the AC power supply line.
(Note-4): For the electrical communication port.
(Note-5): AV: Average value
The standards relevant to the EMC Directive are listed in the table below.
Test item
Radio waves from the product are
(Note-1)
measured.
(Note-3)
Noise from the product to the power
(Note-4)
line and electrical communication port
is measured.
Immunity test in which electrostatic
discharge is applied to the product.
Immunity test in which electric fields
(Note-1)
are radiated to the product.
Immunity test in which burst noise is
applied to the power cable and signal
line.
Immunity test in which surge is applied
to the power line and signal line.
Immunity test in which high frequency
noise is applied to the power line and
signal line.
(Note-3)
Immunity test in which power supply
has short interruptions.
(Note-3)
Test in which voltage dip is applied to
the power supply.
(Note-3)
Immunity test in which voltage dip is
applied to the power supply.
Test details
7 - 2
Standard value
(Note-2)
30M-230MHz QP
: 40dBµV/m
(10m (32.81ft.) in measurement range)
230M-1000MHz QP: 47dBµV/m
(10m (32.81ft.) in measurement range)
AC power line
0.15M-0.5MHz QP
: 79dBµV
(Note-5)
AV
: 66dBµV
0.5M-30MHz
QP: 73dBµV
AV: 60dBµV
Electrical communication port
0.15M-0.5MHz QP, AV: Logarithmic
decrease
0.5M-30MHz
QP: 87dBµV
AV: 74dBµV
8kV: 10 times at 1 second interval,
Air discharge
4kV: 10 times at 1 second interval,
Contact discharge
80-1000MHz 10V/m,
1400M-2000MHz 3V/m,
2000M-2700MHz 1V/m,
80%AM modulation @1kHz
AC power line: ±2kV/5kHz
DC power line: ±2kV/5kHz
I/O, communication line: ±1kV/5kHz
AC power line
Common mode: ±2.5kV
Differential mode: ±1.5kV
DC power line
Common mode: ±0.5kV
Differential mode: ±0.5kV
I/O, communication line
Common mode: ±1kV
0.15-80MHz,
80%AM modulation @1kHz, 10Vrms
0% of rated voltage, 250cycle
40% of rated voltage, 10cycle
70% of rated voltage, 25cycle
0% of rated voltage, 0.5cycle 20 times