APPENDICES

APPENDIX 1.4 Differences between I/O signals

I/O setting
Input signal detection
direction
Table 1.4 Differences between I/O signals
Item
• Q170MSCPU's internal I/F
(Input 4 points, output 2 points)
I/O signal
• PLC I/O module
• Intelligent function module
(Note-1): Real input device (PX) or real output device (PY) is in units of 16 points.
• Real input (PX) : 4 points + Dummy (Unsable: Fixed at 0) 12 points
• Real output (PY) : 2 points + Dummy (Unsable: Fixed at 0) 14 points
(Example) When the first I/O No. is set to 0(H).
(1) Q170MS I/O setting
The setting method for the I/O signals of internal I/F is shown below.
Item
First I/O No.
(in units of 16 points)
High-speed read
(Note-1)
setting
Valid on leading edge
(Normally open contact)/
Valid on trailing edge
(Normally closed contact)
Q170MSCPU
(Note-1)
• PX0 to PX3 (Real input), PX4 to PXF (Unsable: Fixed at 0)
• PY0 to PY1 (Real output), PY2 to PYF (Unsable: Fixed at 0)
Setting for the I/O signals
Setting for the mark detection signal (DI)
Setting range
Used/Unused
0000 to 0FF0
Used/Unused
Valid on leading edge
(Normally open contact)
(Note-1): This cannot be set in SV22 advanced synchronous control.
APP - 6
Q173DSCPU/Q172DSCPU
• Built-in interface in Motion CPU
(Input 4 points)
• PLC I/O module
• Intelligent function module
Initial value
Unused
Number of I/O points
0000
must be total of 256
points or less.
Unused
Set the detection
direction of the mark
detection signal (DI).
(Note-1)
Remarks