Mitsubishi Electric Q170MSCPU User Manual page 221

Melsec q series, motion controller
Table of Contents

Advertisement

APPENDICES
Bit device
Setting range
0 to 1FFF
X(PX)
Y(PY)
0 to 8191
M
B
SM
10000.0 to (10000+p-1).F
U \G
(Note-1): The range of "PXn+4 to PXn+F" cannot be used (fixed at 0) for the input device (PXn+0 to PXn+F)
(Note-2): The range of M0 to M12287 is valid in the SV22 advanced synchronous control.
(Note-3): "p" indicates the user setting area points of the Multiple CPU high speed transmission area for each CPU.
2) Bit device
(Note-1)
0 to 1FFF
(Note-2)
• Operation cycle 222[µs]
0 to 1FFF
• Operation cycle 444[µs] or more : 444
0 to 1999
(Note-3)
allocated to the built-in interface in Motion CPU (DI). (n: First input No.)
Detection accuracy [µs]
APP - 8
Signal detection direction
(Leading edge/Trailing edge)
Set direction in the mark
: 222
detection signal detection
direction.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q170mscpu-s1

Table of Contents