2 SYSTEM CONFIGURATION
Motion controller
Battery type
Q7BAT
Q170MSCPU-S1
(Large capacity)
(Note-1): The battery consumption represents consumption of the Motion controller battery energy.
The larger the battery consumption value is, the more battery per time unit is consumed.
Refer to the "QCPU User's Manual (Hardware Design, Maintenance and Inspection) for details.
(Note-2): The actual service value indicates the average value, and the guaranteed value indicates the minimum value.
(Note-3): The power-on time ratio indicates the ratio of Motion controller power-on time to one day (24 hours).
(When the total power-on time is 17 hours and the total power-off time is 7 hours, the power-on time ratio is 70%.)
(Note-4): The guaranteed value (MIN) ; equivalent to the total power failure time that is calculated based on the characteristics value of the
memory (SRAM) supplied by the manufacturer and under the storage ambient temperature range of -25°C to 75°C (-13 to 167°F)
(operating ambient temperature of 0°C to 55°C (32 to 131°F)).
(Note-5): The guaranteed value (TYP) ; equivalent to the total power failure time that is calculated based on the normal air-conditioned
environment (40°C (104°F)).
(Note-6): The actual service value (Reference value) ; equivalent to the total power failure time that is calculated based on the measured
value and under the storage ambient temperature of 25°C (77°F). This value is intended for reference only, as it varies with
characteristics of the memory.
(Note-7): Battery consumption 1 cannot be used in Q170MSCPU.
Table 2.2 Battery life of Q6BAT/Q7BAT (continued)
Battery
Power-on
consumption
time ratio
(Note-1)
(Note-3)
0%
30%
1
50%
70%
100%
0%
30%
2
50%
70%
100%
0%
30%
3
50%
70%
100%
POINTS
The self-discharge influences the battery life even without a connection to the
Motion controller. The battery should be replaced approximately every 4 to 5 years.
In addition, replace the battery with a new one in 4 to 5 years even if the total
power failure time is the guaranteed value or less.
Battery life (Total power failure time) [h]
Guaranteed
Guaranteed
(Note-4)
(Note-5)
value
value
(MIN)
(TYP)
(75°C (167°F))
(40°C (104°F))
43800
43800
7600
21500
10900
30400
15100
42000
24700
43800
43800
4100
11900
5900
17000
8200
23600
13600
38600
43800
43800
2 - 73
(Note-2)
Actual service
(Note-6)
value
Backup time
(Reference value)
after alarm
(TYP)
(25°C (77°F))
43800
25000
35300
90
(After SM51/
SM52 ON)
43800
13750
19500
27000
43800