EDITION 05/2015
OPERATING MANUAL
10.3.3
CLEANING THE PARTS AFTER DISASSEMBLY
Please note:
All reusable parts (except for the parts conducting high-voltage such as cascade,
adapter, plug compl. etc.) should be cleaned thoroughly using a suitable cleaning
agent.
The adapter, connector, inside handle and all dismantled parts must be clean and
dry after cleaning. Care should be taken that these parts remain free of solvents,
grease or sweat from the hands (salt water). Clean and mount wearing gloves.
Spare parts may have safety-relevant properties.
Only repair and replace parts that are listed in the "Spare Parts" chapter and that are
assigned to the device.
Defective parts, O-rings and seal sets must always be re-placed.
Incompatibility of cleaning agent and working medium!
Risk of explosion and danger of poisoning by toxic gases.
In Chapter 14 the part numbers for gun spare parts can be found as well as for wearing
parts such as seals.
ORDER NUMBER DOC2319150
ATTENTION
WARNING
Examine the compatibility of the cleaning agents and working
media on the basis of the safety data sheets.
69