Safety Checks - WAGNER GM 50000EAC Translation Of The Original Operating Manual

Electrostatic aircoat spray gun
Table of Contents

Advertisement

EDITION 05/2015
OPERATING MANUAL
Incorrect maintenance/repair!
Danger to life and equipment damage.
8.2.3

SAFETY CHECKS

For the safe operation of electrostatic manual coating systems for fl ammable liquid coating products, intervals for
periodical inspections are defi ned as follows:
Inspection point
Gun cleaning, gun fl ushing
Hoses, tubes, couplings
Grounding
Inspection for damage
Locking of the technical ventilation with the
electrostatic manual spraying unit
The above recommended intervals are maximum values and may be modifi ed by the operator depending on
the local and operational conditions and the contamination.
Damaged devices must be decommissioned and repaired immediately.
ORDER NUMBER DOC2319150
DANGER
Only a WAGNER service center or a suitably trained person may
carry out repairs and replace parts.
Only repair and replace parts that are listed in the Chapter
"Spare parts" and that are assigned to the unit.
Before all work on the device and in the event of work interruptions:
- Switch off the energy and compressed air supply.
- Relieve the pressure from the spray gun and device.
- Secure the spray gun against actuation.
Observe the operating manual and service manuals at all times
when carrying out work.
Inspection interval Remarks
daily
Chapter 4.2.4, Chapter 8.1.3
daily
Chapter 8.2.4
weekly
Chapter 4.2.2, Chapter 6.4.5
weekly
Chapter 8.1.3, 8.2, 10
annually
Chapter 6.4.2
59