6.6

COMMISSIONING

6.6.1

SAFETY INSTRUCTIONS

Observe the safety instructions in Chapter 4 and Chapter 8.1.2.
Observe the general rules for making adjustments to the spray gun.
6.6.2

PREPARATION FOR COMMISSIONING

Impurities in the spraying system!
Spray gun blockage.
Flush the spray gun and paint supply with a suitable fl ushing agent before
commissioning.
6.6.3
COMMISSIONING
The following points must be noted:
Grounding see Chapter 6.4.5. Make sure that all other conductive parts within the
work area are grounded.
Connect the product hose to the spray gun and the product pump.
Check that all product-conveying connections are correctly connected.
Connect air hose to spray gun and to supply of oil-free dry air, approx. 0.25 MPa;
2.5 bar; 36 psi. For compressed air quality see Chapter 5.5.
Check that all air-conveying connections are correctly connected.
Connect the electric cable to the spray gun and to the VM 5000 or VM 500 control
unit.
Visually check the permissible pressures for all the system components.
Check the level of the separating agent in the WAGNER pneumatic pump and fi ll the
separating agent up if necessary.
Provide product tank, tanks for fl ushing agent and an empty tank for return fl ow.
Connect the system with a secured gun to the air and power supply.
A basic fl ushing of system must be carried out before commissioning.
Make sure that no nozzle is inserted into the gun.
ORDER NUMBER DOC2319150
NOTICE
Chapter 7.2.2