EDITION 05/2015
OPERATING MANUAL
Cable connections
Only cable assigned to the device may be used (see Chapter 13).
Permissible Device Combinations
The GM 5000EAC manual spray gun may only be connected to the control units listed
below:
- VM 500 control unit
- VM 5000 control unit
Incorrect use!
Risk of injury and damage to the device.
3.3

TYPE PLATE

J. Wagner AG
CH-9450 Altstätten
GM 5000EAC
Art. Nr.:
2309823
high voltage:
max. 80kV DC
current:
max. 100μA DC
max. mat. pressure:
25MPa; 250bar; 3626psi
max. air pressure:
0.8MPa, 8bar; 116psi
ORDER NUMBER DOC2319150
WARNING
Connect the GM 5000EAC manual spray gun only to original
WAGNER control units.
1 Warning: Danger of becoming injured
by high-pressure jet
2 Device type
3 Article number
4 Maximum high-voltage
5 Maximum current
6 Maximum product pressure
7 Maximum air pressure
8 Do not dispose of used electrical
equipment with household refuse
9 Identifi cation and test centre
10
Serial number
The serial number (S) on the
underside of the handle.
B_04366
II 2 G
0102
EEx 0.24 mJ
SIRA 11 ATEX 5374X
For Electro. Fin. Appl. CL. I, GP. D, Spray Matl.
S
8
9
10
B_03558
13