Emergency Deactivation; General Rules For Making Adjustments To The Spray Gun - WAGNER GM 50000EAC Translation Of The Original Operating Manual

Electrostatic aircoat spray gun
Table of Contents

Advertisement

EDITION 05/2015
OPERATING MANUAL
Discharge of electrostatically charged components in atmospheres
containing solvents!
Explosion hazard from electrostatic spark-over.
7.2.1

EMERGENCY DEACTIVATION

In the case of unforeseen occurrences, proceed as follows:
1. Switch off control unit.
2. Close the compressed air supply.
3. Relieve pressure according to the operating manual of the product pressure generator.
4. Point the spray gun toward the grounded collecting tray.
5. Pull the trigger of the spray gun until no further pressure is present.
7.2.2

GENERAL RULES FOR MAKING ADJUSTMENTS TO THE SPRAY GUN

High-voltage fi eld!
Danger to life from malfunction of heart pacemakers.
Make sure that persons with pacemakers:
High-pressure spray jet!
Danger to life from injecting paint or solvent.
ORDER NUMBER DOC2319150
WARNING
Use gun only with fi tted nozzle, air cap and union nut.
Tighten the union nut, especially with nozzle in the cleaning
position.
DANGER
Do not work with the electrostatic spray gun.
Do not enter the high-voltage area.
WARNING
Never reach into the spray jet.
Never point the spray gun at people.
Consult a doctor immediately in the event of skin injuries caused
by paint or solvent. Inform the doctor about the paint or solvent
used.
Never seal defective high-pressure parts, instead relieve the
pressure from them and replace them.
Wear the appropriate protective clothing, gloves, eyewear and
respiratory protection.