OPERATING MANUAL
Exploding gas / air mixture!
Danger to life from fl ying parts and burns.
Flush spray gun
1. Switch off control unit.
2. Relieve pressure
3. Close air pressure regulator.
4. Connect spraying system to fl ushing agent supply in accordance with operating
manual for the pump.
With round jet nozzle fi tted:
5. Use nozzle spanner to loosen nozzle insert by a half turn.
6. Point the spray gun toward the collecting tray and actuate the trigger. Flush the
gun thoroughly as soon as clean fl ushing agent emerges.
7. Relieve pressure
8. Re-tighten the nozzle insert.
9. Remove fl ushing agent supply.
With fl at jet nozzle fi tted:
5.
Dismount AirCoat nozzle and clean separately
6.
Point the spray gun toward the collecting tray and actuate the trigger.
7.
Flush the gun thoroughly as soon as clean fl ushing agent emerges.
8.
Relieve pressure
9.
Remove fl ushing agent supply.
Blowing out the air passages of the spray gun
10. Close pump pressure regulator. Switch on compressed air supply and open air pressure
regulator.
11. Actuate the trigger of the spray gun and thoroughly blow out the air passages.
12. Switch off the compressed air supply.
Clean the outside of the spray gun
13. Clean the spray gun body and other components of the spraying system with a
cleaning agent recommended by the lacquer manufacturer and dry with a cloth or
blow gun.
Cleaning the nozzle parts
Eliminating nozzle clogging
ORDER NUMBER DOC2319150
DANGER
Never spray into a closed tank.
Ground the tank.
Chapter 7.3.4.
Chapter 7.3.4.
Chapter 7.3.4.
see Chapter 7.3.9
see Chapter 7.3.10
Chapter 7.3.8.