Cleaning The Parts After Disassembly - WAGNER GA 5000EAC Operating Manual

Table of Contents

Advertisement

Operating manual GA 5000EAC Electrostatic Automatic Spray Gun (AirCoat)
10   Repairs
9
1. Loosen clamping screw (1) with assembly tool (5).
2. Remove valve rod unit (2, 3, 4, 6).
3. Only as necessary: Remove rod seal (10). Do not damage the housing in the process.
10.4.3   Cleaning the Parts after Disassembly
Please note:
1. All reusable parts (except for the parts conducting high voltage such as adapter etc.)
should be cleaned thoroughly using a suitable cleaning agent.
2. The adapter, plug and all dismantled parts must be clean and dry after cleaning. Care
should be taken that these parts remain free of solvents, grease or sweat from the
hands (salt water). Perform cleaning and mounting tasks wearing gloves.
3. Spare parts may have safety-relevant properties. Only repair and replace parts that are
listed in the spare parts chapter and that are assigned to the device.
4. Defective parts, O-rings and seal sets must always be replaced.
WARNING
Incompatibility of cleaning agent and working medium!
Risk of explosion and danger of poisoning by toxic gases.
4 Examine the compatibility of the cleaning agents and working media on the basis of
the safety data sheets.
In chapter Spare Parts [8 75] the order numbers for gun spare parts can be found as well as
for wearing parts such as seals.
Order number 2360922 | Edition 09/2022
B_05785
1
3
10
5
SW5
SW7
SW7
4
2
6
7
SW8
59