GUN CABLES AND GUN CABLE EXTENSIONS

Sparks form when the plug is removed!
Explosion hazard.
When using the spray gun in potentially explosive areas:
The following points must be noted:
The cable connection to the gun and the connection to a cable extension may not be
disconnected or connected in a potentially explosive area.
Only disconnect or connect all cable extensions from the gun cable and the cable
extension when the control unit is switched off .
In order that the GM 5000EA spray gun is grounded, it must be connected via the gun
cable with the VM 500 or VM 5000 control unit.
Gun cable is available in various lengths. Order No., see Chapter 13.4.3.
Attention: gun cable to control unit
Secure the cover sleeve with the warning sign by means of the screw (84) on the connector.
Warning:
"Do not disconnect under voltage"
B_03691