A.1.4

Data record 72 - Log list - Read device error

Byte
0 ... 3
4 ... 5
6 ... 9
10 ... 11
etc.
120 ... 123
124 ... 125
This data record can accommodate 21 entries. When all locations have been written, the first
entry is overwritten again.
Note
The newest entry is entered at the end of the data record. The remaining entries are moved
up one entry.
The following alarms can be entered:
Object No.
452
1466
1467
1468
1417
PROFINET Communication Module for SIRIUS Soft Starter 3RW44
Manual, 12/2013, A5E31996495002A/RS-AA/001
Meaning
Operating hours
device
Object number
device error
Operating hours
device
Object number
device error
Operating hours
device
Object number
device error
Device error alarms
Heat sink thermistor defective
Switching element 1 failed
Switching element 2 failed
Switching element 3 failed
Bypass element defective
A.1 Data formats and data records
Value range
Increment
0 ... 2
s
1 second
32
0 ... ±32767
1
0 ... 2
s
1 second
32
0 ... ±32767
1
0 ... 2
s
1 second
32
0 ... ±32767
1
Appendix
Comment
Entry 1 = oldest
entry
Entry 2 = second
oldest entry
Entry 21 = last,
newest entry