Data Record 165 - Read/Write Comment - Siemens SIRIUS PROFINET Manual

Industrial controls, communication module for soft starter
Table of Contents

Advertisement

Object
Byte
Meaning
Bit
No.
181
8
Brightness lighting
4...7
180
9
Contrast display
182
10
Response of LEDs to fault
0...3
183
10
Response of LEDs to warning
4...7
11
Reserved = 0
184
12
Response time keys
185
13
Auto repeat speed
186
14
Auto repeat time
187
15
OCM keys activity monitoring time
16 ... 19
Reserved = 0
A.1.18

Data record 165 - Read/write comment

You can save any text containing up to 121 characters (max. 121 bytes) in the soft starter,
e.g., for system documentation.
Byte
Header
0
1
2 ... 3
Comment
4 ... 124
PROFINET Communication Module for SIRIUS Soft Starter 3RW44
Manual, 12/2013, A5E31996495002A/RS-AA/001
Communication parameters
Bit
Coordination
Reserved 1
Reserved 2
Comment data
A.1 Data formats and data records
Value range [coding]
Lighting on [0]
Off with time delay [4]
Off [5]
0 ... 100 % [0 ... 20]
Unchanged [0]
On (1)
Blinking [2]
Flickering [3]
Unchanged [0]
On (1)
Blinking [2]
Flickering [3]
10 ... 100 % [2 ... 20]
10 ... 100 % [2 ... 20]
10 ... 250 ms [2 ... 20]
0 ... 1800 s [0 ... 60]
Value range [coding]
0x20 Write via C1 channel (PLC)
Appendix
Factor
5 %
5 %
5 %
5 ms
30 s