Dedicated I/O signal
3.4.3

Analog input signals and pulse train input signals

Function
Terminal 1
Frequency (speed)
command
Frequency setting
auxiliary
Override
Magnetic flux command
Regenerative torque limit
Torque command
Stall prevention operation
level
Torque limit
Forward/reverse rotation
speed limit
Torque bias
Function
Terminal 1 Terminal 2 Terminal 4
Dancer signal input selec-
tion
Pr. 731
Dancer main speed com-
mand input selection
Pr. 732
Line speed input selection
Pr. 763
Taper setting analog input
selection
Pr. 733
Dancer tension setting input
selection
Pr. 734
*1
Can be set when Pr. 291 = "1, 11, 21, or 100".
*2
Setting Pr. 785 = "2" sets the taper ratio setting as the terminal 4 input regardless the Pr. 733 setting.
REMARKS
• While the dancer/tension control selection X83 signal is ON, the setting values of Pr. 731 to Pr. 734 and Pr. 763 have higher precedence
over the other assigned terminal settings such as Pr. 868, Pr. 785 = "1", and Pr. 406. (Example: When Pr. 731 = "5" and Pr. 868 = "0", the
terminal 1 is set to the dancer signal input.)
• For the taper setting analog input, the setting of Pr. 785 Terminal 4 function setting has higher precedence.
• While tension control is valid (Pr. 800 = "6 or 16"), the following parameter settings are invalid: Pr. 731 Dancer signal input selection,
Pr. 732 Dancer main speed command input selection, and Pr. 734 Dancer tension setting input selection.
• The dedicated-function parameters take the following precedence over each other. When several functions are assigned to a terminal,
input to the function of lower precedence is regarded as 0.
Terminal 4 function setting (Pr. 785 = "2") > Pr. 731 Dancer signal input selection > Pr. 763 Line speed input selection > Pr. 732 Dancer main speed
command input selection > Pr. 733 Taper setting analog input selection > Pr. 734 Dancer tension setting input selection.
18
Analog input
Terminal 4
Terminal 2
Pr. 868
Pr. 785
0
1
2
3, 4
4
4
5
6
Analog input
5
3
5
3
5
3
5
3
5
3
Single-phase pulse
Terminal 6
Terminal
(FR-A7AZ)
JOG
Pr. 406
Pr. 291
1, 11, 21,
1
0
100
1
1
2
3, 4
4
4
5
6
Single-phase pulse
Terminal 6
Terminal
FR-A7AZ
JOG
4
6
4
6
1
4
6
1
4
6
*2
4
6
Encoder
pulse train
train input
input
FR-A7AP/
FR-A7AL
FR-A7AL
: Setting available, : Setting not available
Encoder
pulse train
train input
input
FR-A7AP/
FR-A7AL
FR-A7AL
7
2
*1
7
2
*1
: Setting not available
Refer to
page
Refer to the
Instruction
Manual
(Applied) of
FR-A700 series
Refer to
page
27
43
33
51, 61
51