4.4.9

Auto logout

Setting the automatic logout
On this page, set the times after which there is an automatic logout from WBM or the CLI
following user in activity.
If you have been logged out automatically, you will need to log in again.
Note
No automatic logout from the CLI
If the connection is not terminated after the set time, check the setting of the "keepalive"
function on the Telnet client. If the set time interval is less than the configured time, the lower
value applies. For example, you have set 300 seconds for the automatic logout and 120
seconds is set for the "keepalive" function. In this case, a packet is sent every 120 seconds
that keeps the connection up.
Procedure
1. Enter a value of 60-3600 seconds in the "Web Base Management (s)" input box. If you
enter the value 0, the automatic logout is disabled.
2. Enter a value of 60-600 seconds in the "CLI (TELNET, SSH) (s)" input box. If you enter
the value 0, the automatic logout is disabled.
3. Click the "Set Values" button.
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02
Configuring with Web Based Management