Traps - Siemens SIMATIC NET SCALANCE S615 Configuration Manual

Industrial ethernet security web based management
Hide thumbs Also See for SIMATIC NET SCALANCE S615:
Table of Contents

Advertisement

● "SNMPv1/v2c Read/Write Community String" input box
Enter the community string for read and write access of the SNMP protocol.
● "SNMPv1 Traps" check box
Enable or disable the sending of traps (alarm frames). On the "Trap" tab, specify the IP
addresses of the devices to which SNMP traps will be sent.
● "SNMPv1/v2c Trap Community String" input box
Enter the community string for sending SNMPv1/v2 messages.
Procedure
1. Select the required option from the "SNMP" drop-down list:
– "-" (disabled)
– SNMPv1/v2c/v3
– SNMPv3
2. Enable the "SNMPv1/v2c Read only" check box if you only want read access to SNMP
variables with SNMPv1/v2c.
3. Enter the required character string in the "SNMPv1/v2c Read Community String" input
box.
4. Enter the required character string in the "SNMPv1/v2c Read/Write Community String"
input box.
5. Click the "Set Values" button.
4.4.7.2

Traps

SNMP traps for alarm events
If an alarm event occurs, a device can send SNMP traps (alarm frames) to up to ten different
management stations at the same time. Traps are only sent if the events specified in the
"Events" menu occur.
Note
Traps are sent only when the "SNMPv1 Traps" option was selected in the "General" or
"System > Confguration" tab.
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02
Configuring with Web Based Management
4.4 "System" menu
83