3. Select one of the following options from the "SNTP Mode" drop-down list:
– Poll
– Listen
4. In the "SNTP Server IP Address" input box, enter the IP address of the SNTP server
whose frames will be used to synchronize the time of day.
5. In the "SNTP Server Port" input box, enter the port via which the SNTP server is
available. The port can only be modified if the IP address of the SNTP server is entered.
6. In the "Poll Interval(s)" input box, enter the time in seconds after which a new time query
is sent to the time server.
7. Click the "Set Values" button to transfer your changes to the device.
4.4.8.3

NTP client

Automatic time-of-day setting with NTP
If you require time-of-day synchronization using NTP, you can make the relevant settings
here.
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02
For this mode, you need to configure the following:
- time zone difference (step 2)
- time server (step 4)
- Port (step 5)
- query interval (step 6)
- complete the configuration with step 7.
For this mode, you need to configure the following:
- time difference to the time sent by the server (step 2)
- complete the configuration with step 7.