Description
1.3 Configuration examples
1.3.2

Secure access with S615

Secure remote access and network segmentation with SCALANCE S615
A secure connection for data exchange between an automation plant and remote stations
will be established via the Internet and mobile wireless network. At the same time, a secure
connection will be established when necessary for service purposes. This connection is,
however, restricted to a specific plant section or a specific machine.
In the automation plant, a SCALANCE S615 is connected to the Internet via the ADSL+
router M812-1. The remote stations will be connected to the Internet via the LTE-CP 1243-7
or the HSPA+ router SCALANCE M874-3. The devices establish a VPN connection to the
SCALANCE S615 via which data can be exchanged securely.
When necessary, the service technician connects to the Internet. With the SOFTNET
Security Client, he or she establishes a secure VPN connection to the S615. Various IP
subnets are connected to the S615 between which the integrated firewall checks
communication. This allows the communication of the service technician to be restricted to a
specific IP subnet.