Napt - Siemens SIMATIC NET SCALANCE S615 Configuration Manual

Industrial ethernet security web based management
Hide thumbs Also See for SIMATIC NET SCALANCE S615:
Table of Contents

Advertisement

Description
The table has the following columns:
● Interface
VLAN interface to which the setting relates. Only VLANs with a configured subnet are
available.
● Enable Masquerading
When enabled, with each outgoing data packet sent via this interface, the source IP
address is replaced by the IP address of the interface.
4.7.3.2

NAPT

On this WBM page, you configure port forwarding.
Description
The page contains the following boxes:
● "Source Interface" drop-down list
Interface to which the settings relate. Can only be selected if the device has several
interfaces.
● "Traffic Type" drop-down list
Specify the protocol for which the address assignment is valid.
● "Use Interface IP from Source Interface" check box
When enabled the IP address of the selected interface is used for "Destination IP
Address".
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02
Configuring with Web Based Management
4.7 "Layer 3" menu