5.2
Firmware update - using TFTP
Requirement
● The device has an IP address and is reachable.
● WBM has been started and the "admin" user is logged in.
● There is a TFTP server in the network.
● The firmware file is on the TFTP server.
Procedure
1. Click "System" > "Load&Save" in the navigation area. Click the "TFTP" tab.
2. In "TFTP Server IP Address", enter the IP address of the TFTP server.
3. In "TFTP Server Port", enter the port of the TFTP server
4. If necessary, change the file name in the "Firmware" table row.
5. Select the table row "Firmware" for the "Load file" action. The firmware itself is signed and
encrypted. This ensures that only authentic firmware is downloaded to the device.
6. Click "Set Values". The firmware file is downloaded. The firmware itself is signed and
encrypted. This ensures that only authentic firmware is downloaded to the device.
7. If the file is loaded successfully, the following dialog is displayed
8. Confirm the dialog with "OK". The device is restarted.
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02
Service and maintenance
5.2 Firmware update - using TFTP
171