4.4.7.3

Groups

Security settings and assigning permissions
SNMP version 3 allows permissions to be assigned, authentication, and encryption at
protocol level. The security levels and read/write permissions are assigned according to
groups. The settings automatically apply to every member of a group.
Description
The page contains the following boxes:
● Group Name
Enter the name of the group. The maximum length is 32 characters.
● Security Level
Select the security level (authentication, encryption) valid for
the selected group. In the security levels, the following options:
– No Auth/no Priv
– Auth/no Priv
– Auth/Priv
The table has the following columns:
● Select
Select the row you want to delete.
● Group Name
Shows the defined group names.
● Security Level
Shows the configured security level.
● Read
Enable or disable read access for the required group.
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02
No authentication enabled, no encryption enabled.
Authentication enabled / no encryption enabled.
Authentication enabled / encryption enabled.
Configuring with Web Based Management